UID:dac_DAC 2022_sess168_BEDES119@linklings.com
SUMMARY:Experimental Validation of a Novel Methodology for Electromigratio
 n Assessment in On-chip Power Grids
DESCRIPTION:Back-End Design, Engineering Tracks\n\nExperimental Validation
  of a Novel Methodology for Electromigration Assessment in On-chip Power G
 rids\n\nSukharev\n\nA new methodology for assessment of the electromigrati
 on induced IR-drop degradation in on-chip power/ground grids has been vali
 dated by measurements performed on real silicon. A voltage tapping techniq
 ue was employed for measurement of voltage variations at the power net, st
 ressed with the constant source current at an elevated temperature. A volt
 age-drop between cathode and anode pads exceeding a specified threshold wa
 s considered as a failure. Times-to-failure were measured on a number of p
 ackaged test-grids and used for computing the mean-time-to-failure. The EM
 -induced voltage degradation in this grid was also analyzed with an assess
 ment methodology based on a simulation of stress evolution everywhere in t
 he grid, resulting in a voiding in some of grid branches and corresponding
  resistance increase. The stochastic nature of the EM was captured by intr
 oducing random distributions of atomic diffusivities and critical stresses
  across the grid and iterating them with Monte Carlo loops. A good fit bet
 ween the measured voltage evolution kinetics at different grid nodes and t
 hat predicted by simulation, and the good agreement between measured and s
 imulated failure distributions can be considered as the ever first experim
 ental validation of this EM assessment methodology for on-chip power/groun
 d grids.\n\nTopic: Back-End Design