SUMMARY:Power-Thermal Co-simulation for More Accurately DC IRDrop and temp
 erature distribution of GPGPU’s PCB and Package
DESCRIPTION:Engineering Track Poster, Engineering Tracks\n\nPower-Thermal 
 Co-simulation for More Accurately DC IRDrop and temperature distribution o
 f GPGPU’s PCB and Package\n\nGuan, chu, Chow\n\nThe power delivery n
 etwork of GPGPU faces more challenge as the power are continuously increas
 ing for more computing cores integrated into GPGPU. \nIt will induce the u
 n-even temperature distribution from PCB, substrate to chip level due to I
 2R loss along the PDN. \nThe temperature hotspot will be more prone to app
 ear if the PDN is not well optimized. It will cause EM/IR issues that will
  have great impact on the lifetime. \nIn turn, the temperature will have n
 egative influence on electrical conductivity. Typically, DC IRdrop simulat
 ion will use electrical conductivity under the average temperature is 85C.
  Previously it is the conservative approach as the current is less than 20
 0A at high voltage level. As Moore’s Law move forward, the supply vo
 ltage is continuously decreased to 0.75V for N7 process. For air-cooled co
 ndition, high-performance GPGPU will demand more current > 300A for sustai
 ning the performance. It will draw ~800A if GPGPU changed to liquid-cooled
  condition. These trends will lead to more I2R loss along the PDN that wil
 l make PCB/substrate hotter than 85C average. It is too optimistic for DC 
 IRDrop if it uses traditional assumption. \nAnsys provides the great oppor
 tunity on iterative power-thermal co-simulation with SIwave and Icepak. Th
 e paper will outline the key process on how to build power-thermal co-simu
 lation model. Compared to traditional method, it achieves more accurate si
 mulation results to guide both PDN optimization and thermal/mechanical sol
 ution.\n\nTopic: AI, Back-End Design, Cloud, Embedded Systems, Front-End D
 esign, IP